Q2v4.4. Incorporates
all previous patches for Q2 v4.4.
1.
Q2 Comms Server:
If communication with the Console is lost, the Comms Server will quit, allowing
plate output to continue. (T+1086)
2.
Q2 Engine.exe:
Correct problem resulting in plates (very rarely) being reported as 'Job died'
in the Imager queue; Operation: Add barcode. (T+1063)
3.
Q2 Engine.exe:
Correct problem causing a resident process which dies to be restarted multiple
times. (T+1274)
4.
AddBarcode.exe:
Remove limitation of 1000mm for images into which a barcode can be stitched.
5.
Q2 Engine.exe:
corrected a rare problem causing the next job to be started too early. This has
only ever been seen with InkMonitor. (T+1532)
6.
Q2 Engine.exe:
corrected a rare problem resulting in completed jobs (possibly remaining
highlighted in green), remaining in the queue, with the completion action not
being taken. (T+1552)
Change
|
Severity |
Description |
1,2,3,4,5,6 |
Mild |
Operation could be
confusing or limiting to the user. |
Apply this patch.
Filename |
Version |
Installed
path |
Engine.exe
(Q2) |
v4.4.8 |
D:\Cobra\Q2 v4.4\System |
Q2CommsServer.exe (Q2) |
v1.0.3 |
D:\Cobra\Q2 v4.4\System |
AddBarcode.exe (Q2) |
v1.1.9 |
D:\Cobra\Q2 v4.4\System |
BACK UP THE
EXISTING COMPONENTS SO THIS PATCH MAY BE REMOVED
1.
Log in as
Administrator.
2.
Ensure none of
the Cobra software is running.
3.
Copy the existing
engine.exe and Q2CommsServer.exe from ‘D:\Cobra\Q2 v4.4\System’ to a safe place
elsewhere on the D: drive (in case you need to revert back to these files).
INSTALLATION OF THE PATCH FILES
1.
Ensure none of
the Cobra software is running.
2.
Copy the contents of this patch’s sub-folder named ‘Q2 System components’ to the ‘System’
folder within the folder 'D:\Cobra\Q2 v4.4' replacing the existing files.